  Datasheet File OCR Text:
 Embedded Power for Business-Critical Continuity
LCT43-E Series
47 Watts
Total Power: Input Voltage: # of Outputs: 47 Watts 85 - 264 VAC 120 - 300VDC Triple
Rev. 8.17.06 LCT43-E Series 1 of 3
RoHS
Electrical Specifications
Special Features
* * * * * * * Totally enclosed Universal input Quick Installation Built-in EMI filter Low output ripple Overvoltage protection Overload protection
Input
Input range Frequency Inrush current Input current Efficiency EMI filter 85 - 264 VAC (wide range) 120 - 300VDC 47-63 Hz <20A peak @ 115VAC, <40A peak @ 230VAC cold start @ 25C 1A max. (RMS) @ 115VAC 70% typical at full load FCC Class B conducted and radiated; CISPR 22 Class B conducted and radiated; EN55022 Class B conducted and radiated Bellcore GR-1089-core Class B conducted <3.5 mA @ 50/60 Hz, 264 VAC input
Safety ground leadage current
Output
Maximum power Cross regulation Hold-up time Overload protection 47W with 12CFM forced air 2% on output 1; 5% on outputs 2, 3 10ms @ 47W load, 100VAC input
Short circuit protection on all outputs. Case overload protected @ 110-135% above peak rating Overvoltage protection 5.50-6.75 VDC on main output
Safety
VDE UL CSA CB CE 0805/EN60950 21310-3336-0003 UL60950 E186249 CSA 22.2-234 -950-95-M90 Certificate and report 6593 Mark (LVD)
Embedded Power for Business-Critical Continuity
Rev. 8.17.06 LCT43-E Series 2 of 3
Environmental Specifications
Operating temperature: 0 to 50C ambient derate each output as 2.5% per degree from 50 to 70C Storage temperature: -40C to +85C Temperature coefficient: .04% per C Electromagnetic designed to meet IEC1000-4; susceptibility: -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 5% to 90% .41G from 3 to 500Hz; Spectral break points of .0065 G2/Hz at 10 Hz and 200 Hz and 5 db/octave roll off at each end, 2 hours per axis >300,000 hours at full load and 25C ambient conditions
Vibration:
MTBF demonstrated
Ordering Information
Model Output Minimu Number Voltage m Load LCT43-E +5V +12V -12V 1.0A 0.1A 0A Maximum Load Maximum with Load with Peak Regulati Ripple on2 P/P (PARD)3 Convection 12CFM Forced Load1 Cooling Air 4A 1A 0.5A 7A 1.2A 0.5A 8A 1.5A 0.6A +4/-2% 5% 5% 50mV 120mV 120mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 F (tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges.
Embedded Power for Business-Critical Continuity
Mechanical Drawing Mating Connectors
AC Input: DC Outputs: IEC 320 Molex 15-48-0406 (USA) Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm) 3. 4. 5. Specifications are for convection rating at factory settings at 115VAC input 25C unless otherwise stated Warranty: 1 year Weight: 1.25lbs/0.57kg
Astec Power
Rev. 8.17.06 LCT43-E Series 3 of 3
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Technical Support: +1 888 41 ASTEC or +1 407 241 2752 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Units 2111-2116, Level 21 Tower 1, Metroplaza 223, Hing Fong Road Kwai Fong, New Territories Hong Kong Telephone: +852 2437 9662 Facsimile: +852 2402 4426
Pin Assignments
Connector SK1-1 SK1-2 SK1-3 SK2-1 SK2- 2 SK2- 3 SK2-4 SK2-5 SK2-6 LCT43-E AC Line Ground AC Neutral -12V Com +5V +5V Common +12V
For global contact, visit:
www.astecpower.com technicalsupport@astec.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Astec Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Printed in U S A
Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2006 Emerson Electric Co.